Circulating air-source heat pump
Strong continuous heating capability, suitable for high water‑flow requirements.
It can be directly connected to existing water tank systems or linked across multiple tanks, making it particularly well-suited for retrofit projects.
No water flow regulation module is required, resulting in low cost, a low failure rate, and easy maintenance.
When multiple units are operated in parallel, modular scalability is achieved simply through pump control, offering high engineering flexibility.
It can be directly connected to existing water tank systems or linked across multiple tanks, making it particularly well-suited for retrofit projects.
No water flow regulation module is required, resulting in low cost, a low failure rate, and easy maintenance.
When multiple units are operated in parallel, modular scalability is achieved simply through pump control, offering high engineering flexibility.
Category:
| Product Details
- It boasts strong continuous heating capability, making it ideal for high‑volume water demands; it can be directly connected to existing water tank systems or linked across multiple tanks.
- Particularly well suited for retrofit projects. No flow‑rate adjustment module is required, resulting in low cost and a low failure rate.
- Easy maintenance. When multiple units are operated in parallel, modular expansion is achieved simply through straightforward pump control, offering high engineering flexibility.
| Model number | TR-HP-HW11X | TR-HP-HW19X | TR-HP-HW22X | TR-HP-HW26X | TR-HP-HW37X | TR-HP-HW44X | |
| Power supply | 380V/3N-/50Hz | ||||||
| Rated hot water output (L/h) | 230 | 400 | 465 | 550 | 800 | 950 | |
| Rated Heat Output (kW) | 10.7 | 18.6 | 21.6 | 25.6 | 37.2 | 44 | |
| Rated Power Consumption (kW) | 2.7 | 4.5 | 5.4 | 6.4 | 9.3 | 11 | |
| Winter hot water production (L/h) | 150 | 255 | 290 | 340 | 500 | 590 | |
| Heating Capacity in Winter (kW) | 8 | 13.6 | 15.5 | 18.2 | 26.7 | 31.6 | |
| Winter Power Consumption (kW) | 2.65 | 4.3 | 5.2 | 6.1 | 8.9 | 10.5 | |
| Maximum Operating Power (kW) | 4 | 6.3 | 8 | 8.9 | 12.5 | 16 | |
| Maximum Operating Current (A) | 8 | 12 | 15 | 17 | 24 | 30 | |
| Rated hot water temperature (°C) | 55 | 55 | 55 | 55 | 55 | 55 | |
| Maximum hot water temperature °C | 60 | 60 | 60 | 60 | 60 | 60 | |
| Circulating water flow rate (m³/h) | >2.3 | >4 | >4.6 | >5.5 | >8 | >9.5 | |
| Cyclic takeover specifications | 1-inch external thread | 1-inch external thread | 1-inch external thread | 1.2-inch external thread | 1.2-inch external thread | 1.5-inch external thread | |
| Operating noise (dB) | 63 | 70 | 70 | 70 | 75 | 75 | |
| Appearance Size | Length (mm) | 710 | 750 | 750 | 750 | 1450 | 1480 |
| Width (mm) | 710 | 750 | 750 | 750 | 725 | 900 | |
| Height (mm) | 860 | 1060 | 1060 | 1060 | 1060 | 1650 | |
| Weight (kg) | 115 | 145 | 165 | 180 | 290 | 430 | |
| Quantity (units) | 1 | 1 | 1 | 1 | 2 | 2 | |
| Compressor | Form | Fully enclosed scroll type | |||||
| Refrigerant | R22 (optional R410a) | ||||||
| Wind turbine | Quantity (units) Form | 1 | 1 | 1 | 1 | 2 | 2 |
| Axial fan | |||||||
| Applicable Ambient Temperature Range (°C) | -10~40℃ | ||||||
| Model number | TR-HP-HW51X | TR-HP-HW75X | TR-HP-HW91X | TR-HP-HW110X | TR-HP-HW150X| | TR-HP-HW180X | |
| Power supply | 380V/3N-/50Hz | ||||||
| Rated hot water output (L/h) | 1100 | 1620 | 1950 | 2250 | 3230 | 3900 | |
| Rated Heat Output (kW) | 51 | 75 | 91 | 105 | 150 | 181 | |
| Rated Power Consumption (kW) | 13 | 19 | 23 | 27 | 38 | 47 | |
| Winter hot water production (L/h) | 690 | 980 | 1200 | 1350 | 2000 | 2350 | |
| Heating Capacity in Winter (kW) | 37 | 52 | 64 | 72 | 107 | 126 | |
| Winter Power Consumption (kW) | 13 | 18 | 22 | 25 | 37 | 43 | |
| Maximum Operating Power (kW) | 18 | 26 | 32 | 38 | 52 | 64 | |
| Maximum Operating Current (A) | 34 | 49 | 61 | 72 | 99 | 122 | |
| Rated hot water temperature (°C) | 55 | 55 | 55 | 55 | 55 | 55 | |
| Maximum hot water temperature °C | 60 | 60 | 60 | 60 | 60 | 60 | |
| Circulating water flow rate (m³/h) | >11 | >16 | >20 | >23 | >33 | 42 | |
| Cyclic takeover specifications | 1.5-inch external thread | 2.5-inch flange | 2.5-inch flange | 2.5-inch flange | 4-inch flange | 4-inch flange | |
| Operating noise (dB) | 75 | 80 | 80 | 80 | 85 | 85 | |
| Appearance Size | Length (mm) | 1480 | 1800 | 2000 | 2400 | 2200 | 2200 |
| Width (mm) | 900 | 1050 | 1050 | 1050 | 2000 | 2000 | |
| Height (mm) | 1650 | 2050 | 2050 | 2050 | 2050 | 2050 | |
| Weight (kg) | 500 | 650 | 750 | 800 | 1250 | 1450 | |
| Quantity (units) | 2 | 4 (2 units optional) | 4 (2 units optional) | 4 | 4 | 4 | |
| Compressor | Form | Fully enclosed scroll type | |||||
| Refrigerant | R22 (optional R410a) | ||||||
| Quantity (units) | 2 | 2 | 2 | 3 | 4 | 4 | |
| Wind turbine | Form | Axial fan | |||||
| Applicable Ambient Temperature Range (°C) | -10~40℃ | ||||||
Note: 1. Rated heating test conditions: initial hot water temperature 15°C, final hot water temperature 55°C; ambient dry-bulb temperature 20°C, ambient wet-bulb temperature 15°C.
2. Winter heating test conditions: initial hot water temperature 9°C, final hot water temperature 55°C; ambient dry-bulb temperature 7°C, ambient wet-bulb temperature 6°C.